ABB AF1350-30-11-70 3 Phase Contactor, 1SFL657001R7011

AVAILABLE ON REQUEST

About This Product

Key Features

  • Rated Insulation Volatge: Acc. to UL/CSA: 600 V.

  • Acc. to IEC 60947-4-1 & VDE 0110 (Gr. C): 1000 V.

  • Rated Impulse Withstand Voltage: 8 KV.

  • Degree of Protection: Acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20.

  • Acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00.

Show All Key Features

Product Specifications

Brand
Ambient Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 - 1.1 Uc) -25 to +50deg C
Close to Contactor without Thermal O/L Relay (0.85 - 1.1 Uc) -40 to +70deg C
Close to Contactor for Storage -40 to +70deg C
Auxillary Contact
Auxiliary Contacts NO: 1
Auxiliary Contacts NC: 1
Dimensions
43.8x24.4x39.2 cm
EAN
7320500250143
Frequency
Main Circuit: 50-60 Hz
Item Code
AF1350-30-11-70
Items in Pack
1 Piece
Number of Contacts
Main Contacts NO: 3
Main Contacts NC: 0
Number of Phases
3 Phase
Operating Time
Between Coil Energization and NO Contact Closing: 50 to 80 ms
Between Coil De-Energization and NO Contact Opening: 35 to 55 ms
Between Coil De-Energization and NC Contact Closing: 35 to 55 ms
Between Coil Energization and NC Contact Opening: 50 to 80 ms
Operating Voltage
Main Circuit: 1000 V
Part Number
1SFL657001R7011
Terminal Type
Main Circuit: Bars
Warranty
1 Year
Weight
33000 g
Weight
33 kg
Show All Specifications

Product Details

    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 & 1350 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 55 & 1150 A
      (690 V) 40 & 1350 A
      (1000 V) 40 & 1350 A
      (1000 V) 55 & 1150 A
      (690 V) 70 & 1000 A
      (1000 V) 70 & 1000 A
    • Rated Operational Current AC-3 (Ie):
      (690 V) 55 & 800 A
      (500 V) 55 & 800 A
      (440 V) 55 & 860 A
      (415 V) 55 & 860 A
      (380 / 400 V) 55 & 860 A
      (220 / 230 / 240 V) 55 & 860 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 257 kW
      (380 / 400 V) 475 kW
      (415 V) 500 kW
      (440 V) 560 kW
      (500 V) 560 kW
      (690 V) 800 kW
      (1000 V) 560 kW
    • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
      10 x Ie AC-3
    • Rated Short-time Withstand Current (Icw):
      at 40 & Ambient Temp, in Free Air, from a Cold State 30 s 6000 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 10 s 8000 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 15 min 1600 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 s 10000 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 min 4500 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 10000 A
    • Maximum Electrical Switching Frequency:
      AC-3 60 cycles per hour
      AC-1 60 cycles per hour
      AC-2 / AC-4 60 cycles per hour
    • Rated Operational Current DC-1 (Ie):
      (850 V) 3 Poles in Series, 40 & 1350 A
      (600 V) 3 Poles in Series, 40 & 1350 A
      (220 V) 3 Poles in Series, 40 & 1350 A
    • Rated Operational Current DC-3 (Ie):
      (850 V) 3 Poles in Series, 40 & 1350 A
      (600 V) 3 Poles in Series, 40 & 1350 A
      (220 V) 3 Poles in Series, 40 & 1350 A
    • Rated Operational Current DC-5 (Ie):
      (850 V) 3 Poles in Series, 40 & 1350 A
      (600 V) 3 Poles in Series, 40 & 1350 A
      (220 V) 3 Poles in Series, 40 & 1350 A
    • Mechanical Durability:
      0.5 million
    • Maximum Mechanical Switching Frequency:
      300 cycles per hour
    • Coil Operating Limits:
      (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 &) &
    • Rated Control Circuit Voltage (Uc):
      60 Hz 100 ... 250 V
      50 Hz 100 ... 250 V
      DC Operation 100 ... 250 V
    • Coil Consumption:
      Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A
      Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A
      Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A
      Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
      Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A
      Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A
    • Connecting Capacity Main Circuit:
      Bar 100 mm
    • Connecting Capacity Auxiliary Circuit:
      Solid 2 x 1 ... 4 mm²
      Flexible with Insulated Ferrule 1 x 0.75 ... 2.5 mm²
      Stranded 1 x 1 .... 4 mm²
      Flexible 2x0.75 ... 2.5 mm²
      Flexible with Ferrule 1 x 0.75 ... 2.5 mm²

Maximum Operating Altitude Permissible: 3000 m

Browse through the extensive list of Relays & Contactors at Moglix. Shop online for other ABB Relays & Contactors. available at Moglix in the lowest price range.

Read More

Reviews & Ratings

Be the first one to provide review for this product

Review with images &
earn 5 Mogli Coins!

Frequently Asked Questions  Have doubts regarding this product?

Looking for Relays & Contactors

ABB AF1350-30-11-70 3 Phase Contactor, 1SFL657001R7011

 Purchase item in bulk quantity

 Get best & customise price