No Line-Load bias
Trip free mechanism

AC MCB
Electrical/Mechanical Life:30,000 Cycles

AC MCB
Magnetic Release Setting:(5-10)ln

Low watt loss-almost 50% of the values prescribed by IS/IEC
Large Terminal Screws



3kA Breaking Capacity Handles Moderate Fault Currents
16a Rating for Reliable Single-pole Circuit Protection

Shunt Trip: Bimetal
Rated Impulse Voltage: 440 V

AC MCB
Electrical/Mechanical Life:30,000 Cycles

IP20-finger safety
25 mm² cage terminals








Field-Fittable Auxiliaries for Advance Protection & Monitoring
Higher System Performance with Optimized Cost

Fin ger proof Terminal
Low watt loss-almost 50% of the values prescribed by IS/IEC




Made From Flame Retardant Body which is PBT Known for...

Large Terminal Screws
Air Circulation Channel

Magnetic Release Setting:(3-5)ln
Electrical/Mechanical Life:30,000 Cycles






Magnetic Release Setting:(3-5)ln
Electrical/Mechanical Life:30,000 Cycles


IP20-finger safety
Low watt loss-almost 50% of the values prescribed by IS/IEC




Electrical/Mechanical Life:30,000 Cycles
Magnetic Release Setting:(10-20)ln
Hang on, Loading More
What is a 16 Amp MCB?
A 16 Amp Miniature Circuit Breaker (MCB) is an electrical safety device designed to protect electrical circuits from damage caused by overcurrent, which can include overload and short circuits. The 16 Amp rating indicates the maximum continuous current it can safely handle before tripping.
When should I use a 16 Amp MCB?
A 16 Amp MCB is commonly used for circuits that draw a moderate amount of current, such as those powering general-purpose outlets in a home or office, or specific appliances like washing machines, dishwashers, or small water heaters. Its important to match the MCB rating to the cable capacity and the expected load of the circuit.
What happens if a circuit draws more than 16 Amps?
If a circuit protected by a 16 Amp MCB draws more than 16 Amps for an extended period, the MCB will detect the overcurrent and trip. This means it will automatically interrupt the flow of electricity, preventing overheating of the wires and potential fire hazards.
Can I replace a 10 Amp MCB with a 16 Amp MCB?
It is generally not advisable to replace a lower-rated MCB (like a 10 Amp) with a higher-rated one (like a 16 Amp) without proper assessment. Doing so can overload the wiring, which is only rated for the lower current, leading to overheating and fire risks. Always consult a qualified electrician.
How do I reset a tripped 16 Amp MCB?
To reset a tripped 16 Amp MCB, first identify and rectify the cause of the overload or short circuit. Then, simply push the lever on the MCB back to the on position. If the MCB trips again immediately, there may be a persistent fault that requires professional attention.