Thermal Magnetic Trip Unit with Adjustable O/L & S/C
Current Limiting Type, Direct Mounting Arrangement for Extended Rotary Handle,

I2T ON/OFF for Precise Coordination, Pre Trip Alarm Contact to...
Adjustable Overload with Delay/Short Circuit with Adjustable Delay/Ground Fault &

Double contact structure
ETS (Microprocessor based) Release





Inbuilt ground fault pratecbori available 20% to 100% of tn
Communication using RS485/MOD0JS/Phofibus protocol



Common Internal accessories for the entire range
Thermal magnetic trip unit

Microprocessor based trip unit
Common Internal accessories for the entire range

Microprocessor based trip unit
Innovative Accessories viz. Short Circuit Alarm Switch, Illuminated Handle, Shunt

Thermal magnetic trip unit
Common Internal accessories for the entire range

Common Internal accessories for the entire range
Information on the GO - Unique Knowledge Manager (QR Code)

Microprocessor based trip unit
Innovative Accessories viz. Short Circuit Alarm Switch, Illuminated Handle, Shunt

Common Internal accessories for the entire range
Innovative Accessories viz. Short Circuit Alarm Switch, Illuminated Handle, Shunt






Switch disconnectors
Common Internal accessories for the entire range




Overload Adjustability: Fixed
Short Circuit Adjustability: Fixed

Ics= 50% Icu
Fixed Overload & Fixed Short Circuit Setting


Adjustable Overload from 0.5 - 1.0ln
Communication using RS485/MOD0JS/Phofibus protocol

Adjustable short circuit from 1.5-1 Olr
Provision of theimai memory: OT-J/OFF

Trip free mechanism
FTM (Thermal Magnetic) Release

Fixed Overload
Fixed short circuit

Adjustable short circuit from 1.5-1 Olr
Provision of theimai memory: OT-J/OFF






Hang on, Loading More
What is a 40 Amp MCCB?
A 40 Amp MCCB (Molded Case Circuit Breaker) is an electrical safety device designed to protect electrical circuits from overcurrents, specifically rated for a maximum load of 40 amperes. It interrupts the flow of electricity when it detects a fault, preventing damage to equipment and wiring.
What is the primary function of a 40 Amp MCCB?
The primary function of a 40 Amp MCCB is to provide overcurrent protection. It safeguards electrical systems against overload conditions (where current exceeds the rated value for an extended period) and short circuits (where a sudden, very high surge of current occurs).
Where are 40 Amp MCCBs typically used?
40 Amp MCCBs are commonly used in industrial, commercial, and sometimes residential applications for protecting main power feeds, sub-circuits, motors, transformers, and other electrical equipment that draws up to 40 amps.
What are the key benefits of using a 40 Amp MCCB?
Key benefits include reliable overcurrent protection, enhanced safety by preventing electrical fires and equipment damage, and the ability to be manually reset after a fault. They offer a robust and durable solution for circuit protection.
How does a 40 Amp MCCB differ from a fuse?
Unlike a fuse which is a sacrificial device that must be replaced after it blows, an MCCB is a resettable device. When a fault occurs, the MCCB trips and can be manually reset to restore power once the fault condition is resolved, offering greater convenience and potentially lower long-term costs.