24 hrs Delivery
Electrical & Appliances
Office Supplies
Industrial Tools
Medical & Lab Supplies
Agri & Gardening
Safety Supplies
Construction Materials
Automotive
Packaging & Material Handling




Trip free mechanism
To avoid improper cable termination, safety terminals guide the cable











Padlocking Facility
Integrated Label Channel Holder

Large Terminal Screws
Large Dolly


Air Circulation Channel
Bi-Connect terminal for Cable and Bushbar

Large Dolly
Integrated Label Channel Holder

Magnetic Release Setting:(5-10)ln
AC MCB

Electrical/Mechanical Life:30,000 Cycles
AC MCB

Magnetic Release Setting:(3-5)ln
AC MCB




Electrical/Mechanical Life:30,000 Cycles
Magnetic Release Setting:(5-10)ln





Magnetic Release Setting:(5-10)ln
AC MCB

Bi-Stable Din Clip Position, Air Circulation & Ease of Clamping
High Quality Contact Tips & Energy Saver





Electrical/Mechanical Life:10,000 Cycles
Magnetic Release Setting:(5-10)ln

Magnetic Release Setting:(3-5)ln
Electrical/Mechanical Life:30,000 Cycles

Electrical/Mechanical Life:30,000 Cycles
Magnetic Release Setting:(3-5)ln

Hang on, Loading More
What is a Four Pole MCB?
A Four Pole Miniature Circuit Breaker (MCB) is an electrical safety device that protects a circuit from overcurrents, whether caused by overload or short circuit. It has four poles, meaning it can disconnect all three phases and the neutral conductor simultaneously.
When is a Four Pole MCB typically used?
Four Pole MCBs are commonly used in three-phase electrical systems, particularly where the neutral conductor needs to be protected or switched along with the phase conductors. This is often seen in industrial settings, motor control circuits, and installations with specific earthing requirements.
What is the main advantage of using a Four Pole MCB over a Three Pole MCB?
The primary advantage is the ability to disconnect both the phase conductors and the neutral simultaneously. This ensures complete isolation of the circuit, which is crucial for safety during maintenance or in fault conditions, especially in systems where the neutral conductor carries current or is essential for proper operation.
How does a Four Pole MCB protect against overcurrents?
Like other MCBs, a Four Pole MCB uses thermal and magnetic mechanisms. The thermal element (bimetallic strip) reacts to sustained overloads by bending and tripping the breaker. The magnetic element reacts instantly to high short-circuit currents, causing rapid tripping and disconnection of all four poles.
Are Four Pole MCBs suitable for all electrical installations?
Four Pole MCBs are specifically designed for three-phase systems where neutral switching is required. They are not typically used in single-phase residential installations, which usually employ single or double pole MCBs.
| Latest Models | Price | Discount |
|---|---|---|
| Chint eBG 3A 6kA C-Curve Four Pole Non-RoHS MCB, 187337 | ₹999 | 1% OFF |
| Chint eB 50A 4.5kA C-Curve Four Pole MCB, 186557 | ₹1,009 | 1% OFF |
| Chint NB1-63DC 6A 6kA C-Curve Four Pole MCB, 182731 | ₹2,189 | - |
| Havells Euro-II 63A Four Pole D Curve MCB, DHMGDFPF063 | ₹1,889 | 15% OFF |
| B-Five Bsf 63A Four Pole MCB, Bsf-412 | ₹861 | 22% OFF |
| HPL 10kA 40A Four Pole D Curve Techno N MCB, NTFPD6-32 | ₹1,606 | - |
| Chint NB1-63 50A 5kA C-Curve Four Pole UL MCB, 180220 | ₹1,639 | - |
| Chint NB1-63H 50A 10kA C-Curve Four Pole MCB, 179918 | ₹1,899 | - |
| Chint NB1-63 1A 5kA D-Curve Four Pole UL MCB, 181008 | ₹1,739 | - |
| Chint eB 10A 4.5kA C-Curve Four Pole MCB, 186537 | ₹869 | 1% OFF |