24 hrs Delivery
Electrical & Appliances
Office Supplies
Industrial Tools
Medical & Lab Supplies
Agri & Gardening
Safety Supplies
Construction Materials
Automotive
Packaging & Material Handling

Fin ger proof Terminal
Air Circulation Channel

Cooler Operation
Low power consumption

Safety Terminals
Every device is provided with a dual position DIN rail

Low watt loss-almost 50% of the values prescribed by IS/IEC
Cooler Operation

Cooler Operation
Air Circulation Channel

Ease, Speed & Flexibility of Installation - Biconnect, Line-Load Reversible
Can be Used for DC Application Upto 60V per Pole


Bi-Connect terminal for Cable and Bushbar
Combination Head Captive Screw

Electrical/Mechanical Life:30,000 Cycles
Magnetic Release Setting:(3-5)ln

Magnetic Release Setting:(5-10)ln
Electrical/Mechanical Life:10,000 Cycles




















IP20-finger safety
25 mm² cage terminals

Low watt loss-almost 50% of the values prescribed by IS/IEC
Scratch and solvent resistant body

Low watt loss-almost 50% of the values prescribed by IS/IEC
IP20-finger safety



Air Circulation Channel
Integrated Labour Channel Holder

Shunt Trip: Bimetal
Trip Current: 7-10 times of Input Current


Air Circulation Channel
Integrated Labour Channel Holder


Padlocking Facility
Bi-Connect terminal for Cable and Bushbar
Hang on, Loading More
What is a Four Pole MCB?
A Four Pole Miniature Circuit Breaker (MCB) is an electrical safety device that protects a circuit from overcurrents, whether caused by overload or short circuit. It has four poles, meaning it can disconnect all three phases and the neutral conductor simultaneously.
When is a Four Pole MCB typically used?
Four Pole MCBs are commonly used in three-phase electrical systems, particularly where the neutral conductor needs to be protected or switched along with the phase conductors. This is often seen in industrial settings, motor control circuits, and installations with specific earthing requirements.
What is the main advantage of using a Four Pole MCB over a Three Pole MCB?
The primary advantage is the ability to disconnect both the phase conductors and the neutral simultaneously. This ensures complete isolation of the circuit, which is crucial for safety during maintenance or in fault conditions, especially in systems where the neutral conductor carries current or is essential for proper operation.
How does a Four Pole MCB protect against overcurrents?
Like other MCBs, a Four Pole MCB uses thermal and magnetic mechanisms. The thermal element (bimetallic strip) reacts to sustained overloads by bending and tripping the breaker. The magnetic element reacts instantly to high short-circuit currents, causing rapid tripping and disconnection of all four poles.
Are Four Pole MCBs suitable for all electrical installations?
Four Pole MCBs are specifically designed for three-phase systems where neutral switching is required. They are not typically used in single-phase residential installations, which usually employ single or double pole MCBs.
| Latest Models | Price | Discount |
|---|---|---|
| Havells EURO-II 10A C Curve FP MCB, DHMGCFPF010 (Pack of 3) | ₹3,530 | 59% OFF |
| Havells EURO-II 6A C Curve FP MCB, DHMGCFPF006 (Pack of 3) | ₹3,530 | 59% OFF |
| Havells Euro-II 63A Four Pole C Curve MCB, DHMGCFPF063 | ₹1,661 | 51% OFF |
| Havells EURO-II 16A C Curve FP MCB, DHMGCFPF016 (Pack of 3) | ₹3,530 | 59% OFF |
| Havells EURO-II 50A C Curve FP MCB, DHMGCFPF050 (Pack of 3) | ₹4,318 | 52% OFF |
| Schneider Electric Acti9 xC60 32A B-Curve Four Pole MCB, A9N4P32B, Breaking Capacity: 10kA | ₹1,879 | 45% OFF |
| Siemens Betagard 50A Four Pole D Curve MCB, 5SL74508RC, Breaking Capacity: 15 kA | ₹4,133 | 28% OFF |
| C&S 40A 4 Pole D Curve 10kA WiNtrip2 MCB, CSMBS4D40 | ₹2,454 | 25% OFF |
| C&S Wintrip B Type FP MCB CSMB4B20 20A (Pack of 4) | ₹7,177 | - |
| C&S Wintrip C Type Higher Rating FP MCB CSMB4C50 50A (Pack of 4) | ₹10,418 | - |