24 hrs Delivery
Electrical & Appliances
Office Supplies
Industrial Tools
Agri & Gardening
Medical & Lab Supplies
Safety Supplies
Automotive
Construction Materials
Packaging & Material Handling

Adjustable Short Circuit from 1.4 To 10Xir
Inbuilt Thermal Memory

Impulse Withstand Voltage: 8 kV
Trip Range: 100 A

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Trip Range: 100 A
Impulse Withstand Voltage: 8 kV

Easypact CVS 100 to 630A
Overload Setting (Ir) 0.7 - 1 x In

Easypact CVS 100 to 630A
Overload Setting (Ir) 0.7 - 1 x In

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Easypact CVS 100 to 630A
Overload Setting (Ir) 0.7 - 1 x In

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Easypact CVS 100 to 630A
Overload Setting (Ir) 0.7 - 1 x In

Easypact CVS 100 to 630A
Overload Setting (Ir) 0.7 - 1 x In

Easypact CVS 100 to 630A
Overload Setting (Ir) 0.7 - 1 x In

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A

Easypact CVS 100 to 630A
Overload Setting (Ir) 0.7 - 1 x In

Overload Setting (Ir) 0.7 - 1 x In
Easypact CVS 100 to 630A





Ics= 50% Icu
Optium 1.0 Fixed TM Range & Class II Front Face

Fixed Overload & Fixed Short Circuit Setting
Ics= 50% Icu

Ics= 50% Icu
Fixed Overload & Fixed Short Circuit Setting

Adjustable Overload Setting Ir= 0.4-1xIn
Ics= 100% Icu

Adjustable Short Circuit Current Setting Isd= 1.5-10xIr
Optium 2.1 Electronic/Microprocessor Range & Class II Front Face

Adjustable Short Circuit Current Setting Isd= 1.5-10xIr
Optium 2.1 Electronic/Microprocessor Range & Class II Front Face

Optium 2.1 Electronic/Microprocessor Range & Class II Front Face
Adjustable Overload Setting Ir= 0.4-1xIn

Adjustable Overload Setting Ir= 0.4-1xIn
Ground Fault Setting:- Ig= 0.2-1xIn

Optium 2.1 Electronic/Microprocessor Range & Class II Front Face
Ics= 100% Icu

Adjustable Overload Setting Ir= (0.8 to 1.0)xIn
Short Circuit Setting Fixed

Short Circuit Setting Fixed
Ics= 100% Icu

Ics= 50% Icu
Optium 1.0 Fixed TM Range & Class II Front Face

Optium 1.0 Fixed TM Range & Class II Front Face
Fixed Overload & Fixed Short Circuit Setting

Ics= 50% Icu
Optium 1.0 Fixed TM Range & Class II Front Face

Adjustable Overload Setting Ir= (0.8 to 1.0)xIn
Ics= 100% Icu

Optium 1.0 Fixed TM Range & Class II Front Face
Fixed Overload & Fixed Short Circuit Setting

Ics= 100% Icu
Adjustable Overload Setting Ir= (0.8 to 1.0)xIn
Hang on, Loading More
What is a Four Pole MCCB?
A Four Pole MCCB (Molded Case Circuit Breaker) is an electrical safety device that protects circuits from overcurrents (overloads and short circuits). It features four poles, meaning it can simultaneously interrupt all three phases of an AC power supply and the neutral conductor.
When is a Four Pole MCCB typically used?
Four Pole MCCBs are commonly used in systems with a neutral conductor that needs to be switched for safety, such as in IT power systems or where switching the neutral alongside the live conductors is a requirement for protection or maintenance.
What is the main difference between a Three Pole and a Four Pole MCCB?
A Three Pole MCCB switches and protects the three live conductors of an AC supply. A Four Pole MCCB does the same but also includes a fourth pole to switch and protect the neutral conductor simultaneously.
What are the advantages of using a Four Pole MCCB?
The primary advantage is the complete isolation of all conductors, including the neutral, ensuring enhanced safety during maintenance or fault conditions. This is crucial in specific earthing arrangements where neutral currents might be present.
Can a Four Pole MCCB be used in standard single-phase or three-phase systems?
While a Four Pole MCCB can be used in standard three-phase systems, its often more than necessary unless the neutral requires switching. For standard single-phase systems, a two-pole breaker is typically sufficient.