Location not set

Select delivery location

Cart

24 hrs Delivery

Electrical & Appliances

Office Supplies

Industrial Tools

Agri & Gardening

Medical & Lab Supplies

Safety Supplies

Construction Materials

Automotive

Packaging & Material Handling

Circuit Breaker & Switch Disconnector

Showing 40 out of 632 Products
Sort By:  
Havells DHRMAMDF300063 2 Pole 63 A Residual Current Circuit Breaker
  • Detects Current Leakage Faults

  • Dual Pole Compact Breaker

Havells DHRMAMDF030025 2 Pole 25 A Residual Current Circuit Breaker
4.6 (5 Reviews)
By: Havells
Available on Request
₹5,230
Siemens 5SU14247RC40 40 A Two Pole Residual Current Circuit Breaker
Siemens 5SU16247RC32 32 A Two Pole Residual Current Circuit Breaker
Siemens 5SU13447RC40 40 A Four Pole Residual Current Circuit Breaker
Siemens 5SU14448RC40 40 A Four Pole Residual Current Circuit Breaker
Siemens 5SU14448RC32 32 A Four Pole Residual Current Circuit Breaker
Siemens 5SU13241RC32 32 A Two Pole Residual Current Circuit Breaker
Siemens 5SU14442RC40 40 A Four Pole Residual Current Circuit Breaker
C&S 100 A 4 Pole 300 mA WiNtrip Residual Current Circuit Breaker CSRB4P100A300
  • Equipped with finger protected connection terminals (IP20).

  • Dual termination possible for cable and comb type busbar connection.

C&S 100 A 2 Pole 300 mA WiNtrip Residual Current Circuit Breaker CSRB2P100A300
  • Dual termination possible for cable and comb type busbar connection.

  • Provides  Protection against earth fault/ Leakage current and also fullfill

Havells DHRZAMFF300025 4 Pole 25 A Residual Current Circuit Breaker
4.6 (5 Reviews)
By: Havells
Available on Request
₹6,806
  • Leakage & Overload Protection

  • Safe for Home & Small Setups

Havells DHRZAMFF300063 4 Pole 63 A Residual Current Circuit Breaker
C&S 40 A 4 Pole 300 mA WiNtrip Residual Current Circuit Breaker CSRB4P40A300
  • Equipped with finger protected connection terminals (IP20).

  •  Independent of power supply and line voltage.also  free from external

C&S 80 A 4 Pole 300 mA WiNtrip Residual Current Circuit Breaker CSRB4P80A300
  • Equipped with finger protected connection terminals (IP20).

  • Easy padlocking facility.

C&S 100 A 4 Pole 30 mA WiNtrip Residual Current Circuit Breaker CSRB4P100A30
  • Dual termination possible for cable and comb type busbar connection.

  • High short circuit current withstand capacity -6kA.

C&S 16 A 2 Pole 300 mA WiNtrip Residual Current Circuit Breaker CSRB2P16A300
  • Fire resistant plastic parts to withstand abnormal heating and strong

  • High short circuit current withstand capacity -6kA.

C&S 40 A 4 Pole 30 mA WiNtrip Residual Current Circuit Breaker CSRB4P40A30
  • High short circuit current withstand capacity -6kA.

  • Automatically  measures and disconnect the circuit when earth fault/leakege current

Siemens 5SU14442RC63 63 A Four Pole Residual Current Circuit Breaker
Hager 160A 3 Pole Switch Disconnector For MCCB, HCA160Z
Havells DHRZCMFF030040 4 Pole 40 A Residual Current Circuit Breaker
  • 40 Amp Rating Ensures Safe Operation for Moderate Power Loads

  • Quickly Detects Leakage Currents to Prevent Electric Hazards

ABB 25A Two Pole AC Type RCBO, 2CSR275040R1254
By: ABB
Available on Request
₹4,629
C&S 16 A 2 Pole 30 mA WiNtrip Residual Current Circuit Breaker CSRB2P16A30
  • Easy padlocking facility.

  • Provides  Protection against earth fault/ Leakage current and also fullfill

Siemens 5SM36486RC 100 A 300 mA Residual Current Circuit Breaker
ABB 40A Two Pole AC Type RCBO, 2CSR275040R1404
By: ABB
Available on Request
₹5,964
Siemens 5SM34486RC 100 A 100 mA Residual Current Circuit Breaker
Siemens 5SU13441RC40 40 A Four Pole Residual Current Circuit Breaker
Siemens FUSE SWITCH UNIT 63AMPS 3KL8151-3TA00
By: Siemens
Available on Request
₹3,556
Siemens Heavy Duty Switch Disconnector Fuse Unit
By: Siemens
Available on Request
₹13,224
L&T BG204003 40 A 30 mA Residual Current Circuit Breaker
  • Conforms to IS 12640-1.

  • Operates on Core Balance Current Transformer.

L&T BG410003 100 A 30 mA Residual Current Circuit Breaker
  • Truely current operated - operation even at nominal voltage.

  • Conforms to IS 12640 (Part 1) / IEC 61008-1.

Siemens 5SU16241RC63 63 A Two Pole Residual Current Circuit Breaker

Hang on, Loading More

Reviews for Circuit Breaker & Switch Disconnector

Most Recent Review

|

Verified Purchase

High Safety

Ensures electrical safety.

Vandana | Jun 1, 2024

Buy Circuit Breaker and Switch Disconnector for Safe Electrical Systems 

Having a reliable electric device is really crucial to ensure safety in residential, commercial or industrial areas. That is where one of the essential devices, including circuit  breaker and switch disconnector, comes in the role. They both act as protecting electrical systems from overloads, short circuits and unexpected faults. If you are looking for these devices online, you can find many options, but you need to ensure choosing the reliable device that is built with genuine quality. So make sure to pay attention to the quality, material and more. 

 

What is a Circuit Breaker and Switch Disconnector? 

Circuit breaker switches and switch disconnectors are used to isolate electrical circuits safely. Both the devices are different from each other, so lets understand them- 

 

>> Circuit Breaker 

It is an automatic electrical device that is designed to protect a circuit from damage caused by excess current. This particularly detects faults like fire or equipment failure. 

 

>>Switch Disconnector 

The working mechanism of a breaker follows a specific circuit breaker pattern, where it senses abnormal current and trips instantly.  

 

Types of Circuit Breakers and Switch Disconnectors 

The following are the types of circuit breakers and switch disconnectors and their specifications- 

Common Circuit Breaker Types

 

>> Miniature Circuit Breaker (MCB)

This circuit breaker is best for residential and light commercial applications. It protects against overload and short circuits that are commonly used because of its compact size and affordability. 

 

>> Molded Case Circuit Breaker (MCCB) 

This one is suitable for higher power applications in Industries. MCCB offers adjustable trip settings and higher breaking capacity. 

 

>> Air Circuit Breaker (ACB)

ACB commonly used in large industrial setups for high current protection. This is widely known for reliability in power distribution systems. 

 

>> Residual Current Circuit Breaker (RCCB)

RCCB is designed to protect against earth leakage and electric shocks that makes it crucial for safety focused installations. 

 

>> Vacuum Circuit Breaker (VCB)

VCB commonly used in high voltage applications and known for minimal maintenance requirements.  

 

Types of Switch Disconnectors 

>> Fuse Switch Disconnector: This is a combination of isolation and protection using fuses. 

>> Load Break Switch: This is designed to interrupt load currents safely. 

>> Isolator: This is also called a switch disconnector isolator, that specifically used to ensure complete disconnection during maintenance. 

>> Changeover Switch: This device helps switch between power sources like mains and generators. 

 

What Are the Crucial Things to Check Before Buying Circuit Breakers and Switch Disconnectors 

Shopping for reliable circuit breaker and switch disconnector electric devices is really important to ensure safety, so here are the following things that every buyer needs to check- 

 

Current Rating 

You should first check the current rating of these devices and identify how much load each device can handle. This will help you choose the appropriate and suitable option. Always choose the break that matches your system load requirement, as that helps to avoid frequent tripping or overheating. 

 

Voltage Rating

Next, move forward and ensure the device is compatible with your system voltage. If you choose the wrong voltage rating, it can lead to inefficiency or safety risks. 

 

Breaking Capacity 

Now, look for the breaking capacity and refer to the maximum fault current the breaker can safely interrupt. Higher breaking capacity is important for industrial and heavy duty applications. 

 

Number of Poles 

Moving to another crucial thing that you need to pay attention to is the number of poles. Since circuit breakers come in single pole, double pole, triple pole and four pole configurations. The pole selection depends on whether the application is single phase or three phase. 

 

Trip Curve Characteristics 

Look for the trip curve characteristics, as different applications need different trip curves (B, C, or D). Residential setups typically use B or C curves, while industrial equipment may need D curves. 

 

Build Quality and Safety Standards 

By checking the build quality, you can ensure reliability and long term performance. Along with this, make sure the device complies with safety standards like ISI or IEC certifications. 

 

Application Type

Lastly, understand whether you need protection, isolation or both. By considering these factors, you will get help to decide between a circuit breaker and a switch disconnector. 

 

Shop Circuit Breakers and Switch Disconnectors Online at Moglix

If you are searching for a trusted platform where you can shop confidently, then Moglix is your partner. We have multiple circuit breaker types, and are listed with complete product descriptions, complete specifications and brands like Schneider, ABB, Siemens and many more. On our platform, we ensure easy online ordering, fast delivery right at your doorstep, and on bulk purchase, you can easily get an exclusive offer. Our services are accessible across India and have become one of the trusted e-commerce platforms. Start your shopping today!