ABB AF460-30-11-71 3 Phase Contactor, 1SFL597001R7111

AVAILABLE ON REQUEST

About This Product

Key Features

  • Rated Insulation Volatge: Acc. to UL/CSA: 600 V.

  • Acc. to IEC 60947-4-1 & VDE 0110 (Gr. C): 1000 V.

  • Rated Impulse Withstand Voltage: 8 KV.

  • Degree of Protection: Acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20.

  • Acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00.

Show All Key Features

Product Specifications

Brand
Auxillary Contact
Auxiliary Contacts NO: 1
Auxiliary Contacts NC: 1
Dimensions
18.6x21.6x27.8 cm
EAN
7320500249994
Frequency
Main Circuit: 50-60 Hz
Item Code
AF460-30-11-71
Items in Pack
1 Piece
Number of Contacts
Main Contacts NO: 3
Main Contacts NC: 0
Number of Phases
3 Phase
Operating Time
Between Coil Energization and NO Contact Closing: 50 to 120 ms
Between Coil De-Energization and NO Contact Opening: 48 to 58 ms
Between Coil De-Energization and NC Contact Closing: 45 to 55 ms
Between Coil Energization and NC Contact Opening: 45 to 115 ms
Operating Voltage
Main Circuit: 1000 V
Part Number
1SFL597001R7111
Terminal Type
Main Circuit: Bars
Warranty
1 Year
Weight
12000 g
Weight
12 kg
Show All Specifications

Product Details

    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 & 700 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 55 & 600 A
      (690 V) 40 & 700 A
      (1000 V) 40 & 700 A
      (1000 V) 55 & 600 A
      (690 V) 70 & 480 A
      (1000 V) 70 & 480 A
    • Rated Operational Current AC-3 (Ie):
      (1000 V) 55 & 200 A
      (415 V) 55 & 460 A
      (220 / 230 / 240 V) 55 & 460 A
      (690 V) 55 & 400 A
      (440 V) 55 & 460 A
      (380 / 400 V) 55 & 460 A
      (500 V) 55 & 460 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 132 kW
      (380 / 400 V) 250 kW
      (415 V) 250 kW
      (440 V) 250 kW
      (500 V) 315 kW
      (690 V) 355 kW
      (1000 V) 280 kW
    • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
      8 x Ie AC-3
    • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
      10 x Ie AC-3
    • Short-Circuit Protective Devices:
      gG Type Fuses 800 A
    • Rated Short-time Withstand Current (Icw):
      at 40 & Ambient Temp, in Free Air, from a Cold State 10 s 4400 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 15 min 840 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 s 4600 A
      at 40 & Ambient Temp, in Free Air, from a Cold State 1 min 2500 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
    • Maximum Electrical Switching Frequency:
      AC-3 300 cycles per hour
      AC-1 300 cycles per hour
      AC-2 / AC-4 60 cycles per hour
    • Rated Operational Current DC-1 (Ie):
      (600 V) 3 Poles in Series, 40 & 700 A
      (110 V) 1-Pole, 40 & 700 A
      (110 V) 2 Poles in Series, 40 & 700 A
      (220 V) 3 Poles in Series, 40 & 700 A
    • Rated Operational Current DC-3 (Ie):
      (600 V) 3 Poles in Series, 40 & 700 A
      (110 V) 1-Pole, 40 & 700 A
      (110 V) 2 Poles in Series, 40 & 700 A
      (220 V) 3 Poles in Series, 40 & 700 A
    • Rated Operational Current DC-5 (Ie):
      (600 V) 3 Poles in Series, 40 & 700 A
      (110 V) 1-Pole, 40 & 700 A
      (110 V) 2 Poles in Series, 40 & 700 A
      (220 V) 3 Poles in Series, 40 & 700 A
    • Mechanical Durability:
      5 million
    • Maximum Mechanical Switching Frequency:
      300 cycles per hour
    • Coil Operating Limits:
      (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 &) &
    • Rated Control Circuit Voltage (Uc):
      60 Hz 250 ... 500 V
      50 Hz 250 ... 500 V
      DC Operation 250 ... 500 V
    • Coil Consumption:
      Pull-in at Max. Rated Control Circuit Voltage 60 Hz 950 V·A
      Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A
      Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
      Pull-in at Max. Rated Control Circuit Voltage DC 885 V·A
      Pull-in at Max. Rated Control Circuit Voltage 50 Hz 950 V·A
      Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
    • Connecting Capacity Main Circuit:
      Rigid Al-Cable 2x240 mm²
      Bar 47 mm
      Rigid Cu-Cable 240 mm²
    • Connecting Capacity Auxiliary Circuit:
      Solid 2 x 1 ... 4 mm²
      Flexible with Insulated Ferrule 1 x 0.75 ... 2.5 mm²
      Stranded 2 x 1 .... 4 mm²
      Flexible 2x0.75 ... 2.5 mm²
      Flexible with Ferrule 2 x 0.75 ... 2.5 mm²

Maximum Operating Altitude Permissible: 3000 m