Reliable Operation & Compliance with Safety Standards
Built to Last with Schneider Electric's Quality & Reliability
Ensures Long-Lasting & Consistent Electrical Contact
Delivers Quality & Reliability for Industrial Automation Needs
Dc Ratings Available & Click Fit Type Construction
Versatile Configuration
EasyPact TVS Technology
Ensures Reliable & Efficient Electrical Contactor Operation
Space-Saving Construction without Compromising on Performance
Inbuilt 1NO+1NC auxilliary contact
Precision Engineering for Optimal Power Control
Enhanced Safety Features for Peace of Mind in Operation
Built-in Protection Mechanisms for Longevity & Safety Assurance
Easy Inspection & Replacement of Coils & Contacts
Front On/Off Indication
Inbuilt 1NO+1NC auxilliary contact
Front On/Off Indication
Easy Inspection & Replacement of Coils & Contacts
Provides Dependable Power Switching for Critical Applications
Ensures Secure Power Control & Distribution
Inbuilt 1NO+1NC auxilliary contact
Optimised for AC1/AC3 applications
Coil on top design in 95A and above
Top mounting add-on blocks possible upto 80A
Finger proof terminals upto 40A
DC Ratings Available & Click Fit Type Construction
Easy Inspection & Replacement Of Coils & Contacts
Click fit type construction up to 40A
Optimised for AC1/AC3 applications
Energy Saver Microcontroller Based Power Cut off Timer Protection Against
It has three independent voltage and phase sensing circuits
It protects the motor from single phasing, reverse phasing or
Timer to Automate Operation, Smart Scene Setting & Hassle Free
Voice-enabled Device & Smart Energy Management
Versatile 3-pole Configuration
Wide Range of Applications
High Quality, Long Life, Easy Programming & Human Interface
24 hr format, 10 On/Off Per Day
Timer with Replaceable Batteries Frontier Time Switch & 4 Pin...
Accurate to the Minute Control, Superior Relay & Replaceable Battery
Lcd Fuse Type
3 Phase 4 Wire Kwa Meter Lcd
DC Ratings Available & Click Fit Type Construction
Easy Inspection & Replacement of Coils & Contacts
Inbuilt 1NO+1NC auxilliary contact
Test Button Allows Users to Check Circuits for Proper Operation
Operating Position: Any Position
Can be used with existing MN Range of thermal overload
Finger proof terminals upto 40A
Adjustable Settings for Customized Performance
Auto-reconnect Functionality for Uninterrupted Power Supply
High Quality, Long Life & Easy Programming
24 hr format, 10 On/Off Per Day
Can be used with existing MN Range of thermal overload
Click fit type construction up to 40A
Directly Operated
Direct Mounting on MNX 45-80
Inbuilt 1NO+1NC auxilliary contact
Robust Power Handling
Cyclic Timer & Auto Cut off Countdown Timer Combination
High Quality, Long Life & Easy to Use
Click fit type construction up to 40A
Coil on top design in 95A and above
Click Fit Type Construction Up to 40A
Coil On Top Design in 95A & Above
A control relay is better described as a device that assures that all connections in a specific circuit may be effectively controlled also when situations within the same or related circuits change. Contactors are devices that disrupt an established electrical circuit in a typical setting. Contactors and relays are both electronically charged gadgets used to maintain and monitor the efficiency of electrical circuits. The fact that electric contactors & relays work on the same principle distinguishes them. To put it simply, both of the above devices comprise solenoid valves that are subsequently charged by electricity in order to adjust and regulate the electrical demand.
Relays are devices that hold the terminals of an electronic circuit in response to a change in parameters or circumstances within the same or another linked circuit. In contrast, side contactors are employed to repeatedly break or create contacts in an electrical system under varying situations.
Contactors: A contactor is just an electronic appliance used to turn an electrical circuit on or off. Contactors are small and easy to install in the field. So, when the contactor coil is powered, these connections are generally open and deliver operational energy to the load. Contactors are often used to regulate electric motors.
Thermal Overload Relay: Thermal overload relays seem to be low-cost electromechanical main-circuit protection devices. They provide dependable motor safety in the case of overloading or phase failure. The thermal overload relays with contactors can give a compact beginning solution. The thermal overload relay, used in motor starting circuits, prevents the engine from drawing excess current, damaging the motor insulation.
Smart Relays: Smart Relays are implanted devices you could connect to any electrical system to provide remote wireless operation of everything else attached to that channel. Smart relays are intended to make the electrical cabling of innovative solutions easier. The smart relay is straightforward to set up. Its adaptability and superior performance enable customers to save both money and time.
Overload Relays: Overload relays protect motors by monitoring power in the motor system and closing it whenever an electric overload or a phase breakdown is detected. Because relays are far less expensive than motors, relays provide a cost-effective method of safeguarding motors. When a high-current scenario occurs due to an earth fault, short-circuits, phase breakdown, or mechanical jamming, overload relays turn off electricity to the motor.
Protective Relays: A protective relay seems to be switchgear equipment that identifies a failure and activates the circuit breakers to separate the faulty component from the remainder of the circuit. They are small, self-contained devices capable of detecting unusual circumstances. Protective relays recognize abnormal situations in electronic systems by continuously monitoring electrical values that vary under fault and normal conditions.
Plug-In Relays: To maintain electrical equipment working smoothly, plug-in relays are utilized when machinery or motor must manage a circuit utilizing a lower-power output or when numerous circuits should be managed using a single uniform output. Commonly, plug-in relays are utilized in control and automation systems.
Number of Poles: Electrical contactors are available in three and four-pole configurations. It would be best if you chose the contractor based on the frequency of phases in the load. For example, if you wish to operate a three-phase motor, you need to use a three-pole contactor. When you want to detach the neutral, go with the four-pole version.
Category of Application: Another significant selection element is load characteristics. First and foremost, you should understand the contactor's application and pick the appropriate product based on the load characteristics.
Power and Current: You must select a proper contactor based on the load's power or current. When you choose a tiny contactor, your contacts will wear & stay. This has disastrous implications.
Coil Voltage: It is the voltage used to regulate the coil. The magnetic field affects the location of the primary contacts whenever the coil is powered. The coil could burn if too much electricity is supplied to it. When less voltage is provided to the coils, the power connections perform a constant vibratory pull-and-drop in a relatively short period. That is why you must give the coils the proper control voltage.
L&T: L&T offers unmatched strengths across Tech, Engineering, Architecture, and Production. It retains dominance in all its primary business lines, including over 80 years of a powerful, customer-focused strategy and a constant drive for world-class performance.
Legrand: Legrand seems to be a global leader in the digital and electrical building infrastructure industries. They have been an Indian security industry pioneer for over two decades. You use the worldwide experience to tailor services locally, providing end-to-end services across divisions and sectors ranging from commercial and residential to hotel and industrial. To complement their core offers of circuit breakers & distribution boards, Legrand has gradually established product lines for wiring gadgets, door entry, cable management, & structured cabling.
Schneider: Schneider Electric, originally Schneider Electric SA, is a firm that produces energy control and automation technology and services for the distribution of electricity. Control and automation devices; low voltage equipment and devices; solar & power storage; moderate voltage distributing and network management; and vital energy, cooling, and racking are among its primary items.
C&S: C&S Electric Limited is an Indian electronic and electrical equipment company. It is India's leading exporter of commercial switchgear and power panel board equipment. Electricity production, distribution and distribution, protection, and ultimate consumption are all uses for C&S Electric devices.
You may purchase Contactor Relay from Moglix. Browse the vast assortment on the website to shop online. Our website now offers branded Contactor Relays at competitive pricing with unique discounts. If you've been putting off purchasing branded Contactor Relays due to the high pricing, now is your opportunity to save big! Relays & contactors are employed in lighting setups to power a big office complex or a commercial showroom. These are widely utilized in mines, electric vehicles, telephone exchange networks, trains, computer accessories, remote controls, audio-visual systems, and other applications. One of the distinguishing features of Moglix products is their dependability and conformity to international quality standards.