ABB AL30-30-01 3 Pole DC Contactor, 1SBL283001R8601

AVAILABLE ON REQUEST

About This Product

Product Specifications

Brand
Auxillary Contact
Auxiliary Contacts NO: 0
Auxiliary Contacts NC: 1
Dimensions
5.4x12.53x9 cm
EAN
3471522287861
Frequency
Supply Circuit: 50-60 Hz
Item Code
AL30-30-01
Items in Pack
1 Piece
Number of Contacts
Main Contacts NC: 3
Main Contacts NO: 0
Number of Poles
3 Pole
Operating Time
Between Coil Energization & NO Contact Closing: 55-110 ms
Between Coil De-Energization & NO Contact Opening: 12-18 ms
Between Coil De-Energization & NC Contact Closing: 18-28 ms
Between Coil Energization & NC Contact Opening: 25-75 ms
Operating Voltage
Auxiliary Circuit: 690 V
Main Circuit: 690 V
Part Number
1SBL283001R8601
Terminal Type
Screw Terminals
Warranty
1 Year
Weight
850 g
Weight
850 g
Show All Specifications

Product Details

    • Conventional Free-air Thermal Current (Ith):
      acc. to IEC 60947-4-1, Open Contactors q = 40 deg C 65 A
      acc. to IEC 60947-5-1, q = 40 deg C 16 A
    • Rated Operational Current AC-1 (Ie):
      (690 V) 40 deg C 55 A
      (690 V) 55 deg C 55 A
      (690 V) 70 deg C 39 A
    • Rated Operational Current AC-3 (Ie):
      (220 / 230 / 240 V) 55 deg C 33 A
      (380 / 400 V) 55 deg C 32 A
      (415 V) 55 deg C 32 A
      (440 V) 55 deg C 32 A
      (500 V) 55 deg C 28 A
      (690 V) 55 deg C 18 A
    • Rated Operational Power AC-3 (Pe):
      (220 / 230 / 240 V) 9 kW
      (380 / 400 V) 15 kW
      (415 V) 15 kW
      (440 V) 18.5 kW
      (500 V) 18.5 kW
      (690 V) 15 kW
    • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
      8 x Ie AC-3
    • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
      10 x Ie AC-3
    • Rated Operational Current AC-15 (Ie):
      (220 / 240 V) 4 A
      (24 / 127 V) 6 A
      (380 / 440 V) 3 A
      (500 V) 2 A
      (690 V) 2 A
    • Short-Circuit Protective Devices:
      Auxiliary Circuit - gG Type Fuses 10 A
      gG Type Fuses 63 A
    • Maximum Breaking Capacity:
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 470 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 175 A
    • Maximum Electrical Switching Frequency:
      AC-1 600 cycles per hour
      AC-2 / AC-4 300 cycles per hour
      AC-3 1200 cycles per hour
    • Rated Operational Current DC-13 (Ie):
      (125 V) 1.1 / 138 A
      (24 V) 6 / 144 A
      (250 V) 0.55 / 138 A
      (48 V) 2.8 / 134 A
      (72 V) 2 / 144 A
    • Rated Insulation Voltage (Ui):
      acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
      acc. to UL/CSA 600 V
    • Rated Impulse Withstand Voltage (Uimp):
      8 kV
    • Maximum Mechanical Switching Frequency:
      3600 cycles per hour
    • Coil Operating Limits:
      (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 deg C) deg C
    • Rated Control Circuit Voltage (Uc):
      DC Operation 110 V
    • Coil Consumption:
      Average Holding Value, from Warm State 3.5 W
      Average Pull-in Value, from Cold State 3.5 W
Connecting Capacity Main Circuit:
Flexible with Cable End 2.5 ... 10 mm²
Rigid Cable 2.5 ... 16 mm²
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Cable End 0.75 ... 2.5 mm²
    Rigid Cable 1 ... 4 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:
    M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 deg C
    Close to Contactor for Storage -60 ... +80 deg C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 deg C
    Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 deg C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: A 20 g
    Open, Shock Direction: A 10 g
    Closed, Shock Direction: B1 15 g
    Open, Shock Direction: B1 5 g
    Shock Direction: B2 10 g
    Closed, Shock Direction: C1 20 g
    Open, Shock Direction: C1 8 g
    Closed, Shock Direction: C2 14 g
    Open, Shock Direction: C2 8 g
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Browse through the extensive list of Relays & Contactors at Moglix. Shop online for other ABB Relays & Contactors. available at Moglix in the lowest price range.

Read More

Reviews & Ratings

Be the first one to provide review for this product

Review with images &
earn 5 Mogli Coins!

Frequently Asked Questions  Have doubts regarding this product?