Location not set

Select delivery location

Cart

Electrical & Appliances

Industrial Tools

Office Supplies

Agri & Gardening

Medical & Lab Supplies

Safety Supplies

Construction Materials

Automotive

Packaging & Material Handling

Control Motor Starters

Showing 40 out of 1212 Products
Sort By:  
SKN Bentex BSA 20HP Copper & Metal Three Phase Oil Immersed Semi Automatic Motor Starter
  • It Can Also Be Used for Other Motors by Suitable

  • BSA Star Delta Starters are Oil-immersed & Designed for Semi-Automatic

Vukar BOM-B 1HP Single Phase Semi Automatic Submersible Pump Starter, BOM-B2
  • Overload Protection & Dry Run Protection

  • Water Overflow Stop Timer

L&T MU-2P CS90319KODO-MU-2P Single Phase Starter
3.5 (1 Review)
By: L&T
Available on Request
₹1,475
  • AC-3,3 Phase

24 hrs Dispatch
Havells DOL 2Hp Single Phase Dol Starter
4.4 (7 Reviews)
By: Havells
Available on Request
₹1,906
  • Fire Retardant Low Smoke Internal Wiring & Inbuilt Heavy Duty

  • Single-Phase Water Pump

ARC 5HP Oil Immersed Three Phase Direct On Line Motor Starter, BOI TP
  • Heavy Duty Copper Contact & Motor ON/OFF Indicator

  • Protection from Overload

Crompton 2HP Digital Control Panel for Oil Filled Submersible Pump, CODCP2-ZP
4.4 (5 Reviews)
By: Crompton
Available on Request
₹2,018
  • The Panel is Equipped with Genuine Material Like Wire, Gauges

  • Easy On/Off Operation

Vukar Eco 1.5HP Single Phase Digital Borewell Submersible Starter Panel Board with Dry Run, Overload Protection & On Timer, VDP-SP-Eco
  • Dual Digital Display for Voltage & Ampere

  • Dry Run Protection, Overload Protection, Inbuilt on Timer & 60A

L&T MN 80 FASD Fully Automatic Star Delta Starter SS94705
L&T MK1 4HP 4-6.5A 440V Dol Starter for Submersible Pump, SS96210POTO
4.2 (5 Reviews)
By: L&T
Available on Request
₹2,530
  • Operates Within 4-65A, Suitable for Various Pump Applications

  • Safeguards Submersible Pumps with Robust Overload & Short-Circuit Protection

L&T MN 45 FASD Fully Automatic Star Delta Starter SS94021
  • Protects against Overload and Phase Failure

  • Automates Star-Delta Motor Starting

Vukar Eco 0.5HP Single Phase Digital Borewell Submersible Starter Panel Board with Dry Run, Overload Protection & On Timer, VDP-SP-Eco
  • Dual Digital Display for Voltage & Ampere

  • Dry Run Protection, Overload Protection, Inbuilt on Timer & 60A

Vukar MOA-B 1.5HP Single Phase Digital Monoblock Submersible Motor Starter Panel with Dry Run & Overload Protection, MOA-B3
  • Overload Protection & Dryrun Protection

  • Digital Ampere Display & Digital Voltage Display

Havells DOL 0.5Hp Single Phase Dol Starter
By: Havells
Available on Request
₹1,854
  • Fire Retardent Low Smoke Internal Wiring & Inbuilt Heavy Duty

Vukar BOM-D 2HP Single Phase Digital Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, BOM-D4
  • Overload Protection & Dryrun Protection

  • Digital Ampere Display & Digital Voltage Display

Vukar BOA-C 3HP Automatic Single Phase Digital Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, BOA-C5
  • Digital Ampere Display & Digital Voltage Display

  • Over Voltage Protection & Under Voltage Protection

Vukar BOM-G 0.5HP Single Phase Digital Borewell Submersible Motor Auto Starter Panel with Dry Run & Overload Protection, BOM-G1
  • Digital Ampere Display & Digital Voltage Display

  • Fault Indication, Water Overflow Timer & Site Selectable Power on...

L&T Star Delta Starter MOG H1/S1 with MO 9-18, CS90549 (Pack of 10)
48 hrs Dispatch
Vukar TPM-A 7.5HP Three Phase Digital DOL Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, TPM-A2
  • Digital Ampere Display & Digital Voltage Display

  • Single Phase Preventer & Phase Sequence Detector

48 hrs Dispatch
Vukar BOM-E 1HP Single Phase Digital Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, BOM-E2
  • Overload Protection & Dryrun Protection

  • Fault Indication, Water Overflow Timer, Lug Based ISI Wiring, Metal

Vukar TPM-A 10HP Three Phase Digital DOL Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, TPM-A3
  • Single Phase Preventer & Phase Sequence Detector

  • Fault Indication, Water Overflow Timer & Site Selectable Power on...

Vukar MOA-B 0.5HP Single Phase Digital Monoblock Submersible Motor Starter Panel with Dry Run & Overload Protection, MOA-B1
  • Overload Protection & Dryrun Protection

  • Fault Indication, Fully Automatic Water Level Controller, Including Float Switch

Vukar BOM-D 1HP Single Phase Digital Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, BOM-D2
  • Digital Ampere Display & Digital Voltage Display

  • Over Voltage Protection & Under Voltage Protection

Vukar BOM-E 0.75HP Single Phase Digital Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, BOM-E1
  • Over Voltage Protection & Under Voltage Protection

  • Overload Protection & Dryrun Protection

Vukar BOA-B 1HP Automatic Single Phase Digital Borewell Submersible Motor Starter Panel with Dry Run & Overload Protection, BOA-B2
  • Over Voltage Protection & Under Voltage Protection

  • Fault Indication, Fully Automatic Water Level Controller, Including Float Switch

48 hrs Dispatch
Vukar TPA-B 10HP Three Phase Digital DOL Borewell Submersible Motor Starter Panel, TPA-B3
  • Overload Protection & Dryrun Protection

  • Single Phase Preventer & Phase Sequence Detector

KSB Gardo Plus 10 1.0HP Single Phase Control Panel
By: KSB
Available on Request
₹4,726
KSB Gardo Plus 20 2.0HP Single Phase Control Panel
By: KSB
Available on Request
₹6,278
Crompton 3HP 11-20A Single Phase Mini Starter, CGSM0320C
By: Crompton
Available on Request
₹1,083
  • Customer Care Number: 1800 419 0505

In Demand
Havells URJA 1.5Hp Single Phase Submersible Pump Starter, IHADOAK1FA
4.6 (5 Reviews)
By: Havells
Available on Request
₹5,284
  • Fire Retardent Low Smoke Internal Wiring & Inbuilt Heavy Duty

SKN Bentex Micro Digi 12.5HP Iron MCU Direct On Line Motor Starter
  • It Contains High-Quality Silver-plated Rivets, It Also Contains Long Life

  • It Offers Buzzing, Humming & Chattering Noise-Free Operations that Increase

SKN Bentex Inteli-ON 1HP Iron DC Single Phase Smart Submersible Pump Control Panel
  • Smart & Intelligent Single Phase Submersible Motor Panel Built with...

  • Draw Box is Fabricated from CR Metal Sheet with Best

L&T Entice 20A 2M Charcoal Grey Motor Starter, CB91102MG20 (Pack of 10)
  • Corrosion Resistant, Heat Resistant & Impact Resistant

  • Durable & Easy to Install

L&T Direct-on-Line Starters MN 65 Type
By: L&T
Available on Request
₹17,607
  • AC-3,3 Phase

Arc BSDL 7.5HP Three Phase Air Break Direct On Line Motor Starter
5.0 (1 Review)
By: Arc
Available on Request
₹1,601
  • Overload Protection & MK Type Heavy Duty Contactor

  • High Quality Metal Enclosure Provided

Arc BUDOL 7.5HP Three Phase Air Break Direct On Line Motor Starter
  • Overload Protection & MU Type Heavy Duty Contactor

  • High Quality Metal Enclosure Provided

Havells 12-18.0A 260-440V AC HGS-Fully Automatic Star-Delta Starter, IHHASDTBW (Pack of 2)
  • Customer Care Number: 1800 103 1313

Havells 28-40A 415V HGS Automatic Star Delta Submersible Starter (Standard), IHHSSDXCT (Pack of 2)
  • Customer Care Number: 1800 103 1313

Havells 34-50A 260-440V HGS Automatic Star Delta Submersible Starter (Standard), IHHSSDYCWA (Pack of 2)
  • Customer Care Number: 1800 103 1313

ARC 10HP Oil Immersed Three Phase Direct On Line Motor Starter, BOI TP (Pack of 2)
  • Protection from Overload

  • Heavy Duty Copper Contact & Motor ON/OFF Indicator

Vukar BOM-G 1.5HP Single Phase Digital Borewell Submersible Motor Auto Starter Panel with Dry Run & Overload Protection, BOM-G3 (Pack of 2)
  • Over Voltage Protection & Under Voltage Protection

  • Fault Indication, Water Overflow Timer & Site Selectable Power on...

Hang on, Loading More

Purchase The Best Motor Starters At an Affordable Price

 

Running a motor produces a significant quantity of power. When working with such immense power, it is critical to have a backup plan in place to minimize harm and assure safety in all instances. Control motor starters are usually sized to match the motor & voltage of the application. The Control motor starters are the electrical devices designed to safely start and stop an engine. The Control motor starters, like a relay, turn the power ON/OFF, but without a relay, it also offers low voltage and overcurrent safety. 

 

The Control motor starters are required to start an induction engine. This is due to the low rotor resistance. The rotor impedance of an induction motor is determined by the slip, which refers to the relative velocity of the rotor and stator. The resistance varies in inverse proportion with slip.

 

Types of Control Motor Starters

 

Submersible Pump Starters: Submersible pump starters are the security net, and a submersible starter pump board keeps your supply of water from short-circuiting. They serve both functions by avoiding overloading & short-circuiting. This is simple to accomplish with a basic on/off switch operation. Furthermore, it can begin its high-power capacitors, which can activate the engine even when the voltage appears to be lower than the typical low power. Submersible starters include a water level regulator that will start the engine whenever an empty tank is detected. Whenever the tank is filled, it'll also stop automatically.

 

Automatic Motor Starters: These types of motor starters are widely utilized in low-voltage starting applications, particularly for big motors. Two contractors come in as the engine begins. One contactor activates a transformer circuit, while the other pushes the transformer to a star shape. In the beginning, the tapped output of the transformer is linked to the motor connections. The star contactor activates when the motor achieves between 85 and 90 % of full power, and the transformer thereafter works as a choke to control the current and voltage to the motor. The primary contactor then shuts, and the motor regulator operates as an FVNR, delivering full power to the motor.

 

Manual Motor Starters: This sort of starter is operated manually and requires no prior knowledge. A pushbutton is employed to switch off and on the motor. The technology beneath the button involves a mechanical switching that either breaks or creates the circuit, causing the engine to stop or start. They also defend against overload. Unfortunately, these starters lack LVP (low voltage protection), so they do not terminate the circuit during a power outage. Since the motor resumes when electricity is restored, it might be hazardous in particular applications. As a result, they are employed for low-power engines. A direct on-line starter is a manual starting that protects against overload.

 

Selecting factors When Buying Control Motor Starters

 

Line Power & Contactor Size: Check the Full Load Amperage at the main power voltage you want to offer on your engine or device nameplate. Confirm if the line electricity to the motor is one-phase or three-phase. Select a starter with a current rating greater than the FLA of the motor just at the line voltage you want to utilize.

 

Maintenance ease: Before making a final decision, it is critical to confirm that maintainability is within the capability of the electrical and mechanical teams. Traditional beginning procedures are more suitable for scenarios where the crew has rudimentary instruction. However, further training is needed if a complex beginning and regulating mechanism are required.

 

Comfort Of Use: its connected interface must contain provisions for easy control and feedback, such as clear representations, operator panels, and indications. Diagnostic and repair manuals are also required.

 

Restriction Of Facility Space: The actual floor space offered is important to address, particularly when retrofitting new equipment into an existing location. Extensions could be required, increasing the overall cost of purchasing the equipment. Additional control mechanisms are required when working with current beginning procedures to maintain an appropriate working environment. Heat dissipation allotment for different components like transformers, transistors, and power supply is included.

 

Various Top Brands to Purchase Control Motor Starters

 

Crompton Motor S: Crompton Greaves Consumer Electricals Ltd (commonly known as Crompton) is a Mumbai-based Indian electronic equipment firm. The firm makes available LED lights, fans, motors, and home appliances such as water heaters, air conditioners, and kitchen appliances.


 

L&T: Larsen & Toubro Limited, or L&T, is a Mumbai-based Indian multinational corporation interested in building, engineering, manufacturing, information technology, technology, and financial services. The corporation is ranked among the top 5 construction firms in the globe.


 

KSB: Its extensive range includes a solution for any fluid handling difficulty. KSB is the knowledgeable partner you may depend on for every application, from industrial motors and valves to automation systems for pumps & pump equipment and energy conservation and repair services. You may discover full specs, statistics, and literature about all products in KSB.


 

Siemens: Siemens has already developing and producing world-class control devices for over 125 years. Siemens provides a diverse selection of starters to meet the needs of various industries. These items give a smart, simple, dependable motor starting option. They use tried-and-true Siemens contactors & relays to provide the proper start for motors that require direct online beginning or star Delta beginning.

 

Havells: Havells are well known for their high-quality products. Their dual-coated copper winding wires give high efficiency to the motors. Winding wires can withstand high temperatures, and this protects them from burning. Unlike most of the pumps available in the market have ordinary enameled copper wire or wire windings, which makes them inefficient.

 

Purchase Best Quality Control Motor Starters from Moglix

 

Manual motors are employed to manually turn on and off motors and provide fuse-free safety against overload, short circuits, and phase faults. Moglix's control motor starting category includes a broad range of manual engine starters, underwater pumps, and automatic motor starters to meet the demands of customers. The manual engine starters in this category have an encased and hermetically protected coil that is waterproof & shockproof. Single phase, phasing imbalance, and phasing reversal are all protected by our automated motor starters.

 

Popular Links -
 

Water Pumps | Motors | Control Motor Starters | Pump Accessories | Centrifugal Pumps | Submersible Pumps | Sewage Pumps | Booster Pumps | Shallow Well Pumps | Gear Pumps | Washer Pumps | General Purpose Motors | Submersible Pump Starters | Automatic Motor Starters | Manual Motor Starters | Spring Mounts | Gardening & Landscaping | Electricals | Wires & Cables | Switches & Sockets | Power Generation & Transformers | Micro Drives | Distribution Boards | Relays & Contactors | Electrical Spares & Accessories | Wire & Cable Accessories | HVAC Control Products & Sensors | Switches | Extension Boards | Boxes | Plugs & Sockets | Electrical Sockets | Switch & Socket Combinations | Lamp Holder | Flexicords | Door Bell | Indicator Switch | Motor Starter Switches | Ceiling Rose | Cord Switches | Volume Controller | Telephone Jack | Computer Jacks | Receptors | Plates with Base Frame | Base Frame | Cover Plates | DLP Trunking | Plug & Connectors | Receptacles

Frequently Asked Questions about Control Motor Starters

When Standard starters are sufficient for motor control?

In order to prevent damage from being done to DC motors during startup due to extremely high current and torque, starters are utilised. They achieve this by connecting the motor's armature winding in series with external resistance, which limits the current to a manageable amount.

Why motor starting current is high?

Because the motor's slip is equal to unity at start, the rotor's reactance is large. As the slip decreases, the value of Rr/s rises. The induction motor draws a significant amount of inductive current when it is started because the rotor reactance is greater than the rotor resistance.