Chint NQ2-15P/1 5.5kW 5.5-8A 220V Direct On Line Starter, 493537
Chint NQ2-15N/2 7.5kW 12-18A 220V Direct On Line Starter, 493521
Chint NQ2-15P/1 5.5kW 1-1.6A 415V Direct On Line Starter, 493555
Chint NQ2-15P/1 5.5kW 9-13A 415V Direct On Line Starter, 493557
Chint NQ3-5.5P 5.5kW 1.25-2A 110V Direct On Line Starter, 496384
  • Inspection of Operating Flexibility of the Thermal Relay Inside the

  • Eight-Hour Duty, Uninterrupted Duty & Intermittent Periodic Duty

Chint NQ2-33/1 25kW 30-40A 110V Direct On Line Starter, 493606
Chint NQ3-5.5P 5.5kW 7-10A 110V Direct On Line Starter, 496380
  • Inspection of Operating Flexibility of the Thermal Relay Inside the

  • Eight-Hour Duty, Uninterrupted Duty & Intermittent Periodic Duty

L&T Direct-on-Line Starters MN 25 Type
By: L&T
Available on Request
₹4,656
  • AC-3,3 Phase

SKN Bentex BSA 35HP Three Phase Oil Immersed Semi Automatic Motor Starter with Heavy Wide Copper Kits
  • It Can Also Be Used for Other Motors by Suitable

  • This Starter is Used for the Control & Protection of

Chint NQ3-5.5P 5.5kW 0.4-0.63A 110V Direct On Line Starter, 496378
  • Eight-Hour Duty, Uninterrupted Duty & Intermittent Periodic Duty

  • Inspection of Operating Flexibility of the Thermal Relay Inside the

ARC 15HP Three Phase Motor Control & Protection Unit, Smart DOL Pro DC
  • Digital Overload Protection, Dry Run Protection, High & Low Voltage

  • Digital Voltage & Amp. Meter

Chint NQ3-5.5P 5.5kW 1.6-2.5A 36V Direct On Line Starter, 496426
  • Inspection of Operating Flexibility of the Thermal Relay Inside the

  • Eight-Hour Duty, Uninterrupted Duty & Intermittent Periodic Duty

Chint NQ2-15P/1 5.5kW 0.1-0.16A 220V Direct On Line Starter, 493526
RiM Single Phase 240V Metal Submersible Control Panel with Digital Display for WLC 2HP Water Pump
  • Thermal Relay & Overload Features for Motor Safety

  • Easy-to-follow Wiring & Connection System

Chint NQ2-33P/1 25kW 48-65A 110V Direct On Line Starter, 493636
Chint NQ2-15/1 5.5kW 9-13A 380V Direct On Line Starter, 493498
Chint NQ2-15P/2 7.5kW 9-13A 380V Direct On Line Starter, 493578
SKN Bentex Inteli-ON 15HP Iron Star Delta Three Phase Motor Control & Protection Panel
  • It Controls Much Lower Voltages & Digital Relay Built-in MCU...

  • The Inteli-On Advantage is the Reliability of the DC Contactors

Siemens RAJA+ 15kW 12.5-20A Agriculture Star Delta Starter, 3TE72910AW75
  • High Electrical & Mechanical Life

  • Accurate Protection Under Single Phasing & Overload

Siemens RAJA+ 18.5kW 16-25A Agriculture Star Delta Starter, 3TE72910AW79
  • High Electrical & Mechanical Life

  • No Auto Start only Auto Reset of Bimetal Relay &

Siemens RAJA+ 2.2kW 4-6.3A SS Housing DOL Starter with SPP Birelay, 3TW7291-1AB72
  • 22Kw Motor Capacity with Reliable Performance

  • Integrated Spp Relay for Enhanced Protection

Vukar BOM-G 0.5HP Single Phase Digital Power On Auto Starter Motor Panel Board with Motor Dry Run, Overload, Voltage Protection & Cyclic Timer for Borewell Submersible Pump, BOM-G0
  • Digital Ampere & Voltage Display

  • Motor Overload Protection & Motor Dry Run Protection

Vukar MOA-B 2HP Single Phase Digital Monoblock Submersible Motor Starter Panel with Dry Run & Overload Protection, MOA-B4
  • Digital Ampere Display & Digital Voltage Display

  • Fault Indication, Fully Automatic Water Level Controller, Including Float Switch

L&T 415V 50Hz 3Phase MN 32 Direct On Line Starter SS94353
L&T 415V 50Hz 3Phase MN 25 Direct On Line Starter SS94352
Vukar TPA-O 1HP Three Phase Digital DOL Fully Automatic Water Level Controller with Inbuilt Motor Starter Panel Board & Dual Tank Float Switch Sensor for Open Well/Monoblock Pump, TPA-O0
  • Phase Sequence Detector, Fully Automatic Water Level Controller, Lug Based

  • Fault Indication & Single Phase Preventer

Siemens RAJA+ 0.75kW 1.6-2.5A SS Housing DOL Starter with SPP Birelay, 3TW7291-1AW68
  • Includes Bi-Relay with SPP

Havells ASD 150Hp Single Phase ASD Starter
By: Havells
Available on Request
₹115,380
  • Fire Retardent Low Smoke Internal Wiring

  • Single Phase Preventor & Safety Feature In Ush Button Assembly

Havells 3.8-6A 260-440V Three Phase URJA-DOL Standard Submersible Pump Controller, IHSDOAH1KA
  • Customer Care Number: 1800 103 1313

Havells 3.8-6A Single Phase URJA-Submersible Pump Controller, IHADOAJ1FA
  • Customer Care Number: 1800 103 1313

Havells E-Series 1-1.6A 415V AC Direct Online Starter, IHHDOLFATE
  • Customer Care Number: 1800 103 1313

Havells E-Series 18-25A 415V AC Direct Online Starter, IHHDOLPBTE
  • Customer Care Number: 1800 103 1313

Havells 1.07-1.7A 200-400V URJA-DOL Agri Pump Starter, IHADOAE1L
  • Customer Care Number: 1800 103 1313

Havells 17-25A 415V AC HGS-Fully Automatic Star-Delta Starter, IHHASDVBT
  • Customer Care Number: 1800 103 1313

Havells 1.58-2.5A 200-400V Three Phase URJA-DOL Standard Submersible Pump Controller, IHSDOAF1LA
  • Customer Care Number: 1800 103 1313

Havells ASD 75Hp Single Phase ASD Starter
By: Havells
Available on Request
₹67,237
  • Fire Retardent Low Smoke Internal Wiring

  • Single Phase Preventor & Safety Feature In Ush Button Assembly

Havells 3.8-6A 260-440V Three Phase URJA-ASD Standard Submersible Pump Controller, IHSASAH1KA
  • Customer Care Number: 1800 103 1313

Havells E-Series 1.6-2.5A 415V AC Direct Online Starter, IHHDOLGATE
  • Customer Care Number: 1800 103 1313

Havells 52-75A 260-440V HGS Automatic Star Delta Submersible Starter (Standard), IHHSSD2DW
  • Customer Care Number: 1800 103 1313

Hang on, Loading More

Purchase The Best Motor Starters At an Affordable Price

 

Running a motor produces a significant quantity of power. When working with such immense power, it is critical to have a backup plan in place to minimize harm and assure safety in all instances. Control motor starters are usually sized to match the motor & voltage of the application. The Control motor starters are the electrical devices designed to safely start and stop an engine. The Control motor starters, like a relay, turn the power ON/OFF, but without a relay, it also offers low voltage and overcurrent safety. 

 

The Control motor starters are required to start an induction engine. This is due to the low rotor resistance. The rotor impedance of an induction motor is determined by the slip, which refers to the relative velocity of the rotor and stator. The resistance varies in inverse proportion with slip.

 

Types of Control Motor Starters

 

Submersible Pump Starters: Submersible pump starters are the security net, and a submersible starter pump board keeps your supply of water from short-circuiting. They serve both functions by avoiding overloading & short-circuiting. This is simple to accomplish with a basic on/off switch operation. Furthermore, it can begin its high-power capacitors, which can activate the engine even when the voltage appears to be lower than the typical low power. Submersible starters include a water level regulator that will start the engine whenever an empty tank is detected. Whenever the tank is filled, it'll also stop automatically.

 

Automatic Motor Starters: These types of motor starters are widely utilized in low-voltage starting applications, particularly for big motors. Two contractors come in as the engine begins. One contactor activates a transformer circuit, while the other pushes the transformer to a star shape. In the beginning, the tapped output of the transformer is linked to the motor connections. The star contactor activates when the motor achieves between 85 and 90 % of full power, and the transformer thereafter works as a choke to control the current and voltage to the motor. The primary contactor then shuts, and the motor regulator operates as an FVNR, delivering full power to the motor.

 

Manual Motor Starters: This sort of starter is operated manually and requires no prior knowledge. A pushbutton is employed to switch off and on the motor. The technology beneath the button involves a mechanical switching that either breaks or creates the circuit, causing the engine to stop or start. They also defend against overload. Unfortunately, these starters lack LVP (low voltage protection), so they do not terminate the circuit during a power outage. Since the motor resumes when electricity is restored, it might be hazardous in particular applications. As a result, they are employed for low-power engines. A direct on-line starter is a manual starting that protects against overload.

 

Selecting factors When Buying Control Motor Starters

 

Line Power & Contactor Size: Check the Full Load Amperage at the main power voltage you want to offer on your engine or device nameplate. Confirm if the line electricity to the motor is one-phase or three-phase. Select a starter with a current rating greater than the FLA of the motor just at the line voltage you want to utilize.

 

Maintenance ease: Before making a final decision, it is critical to confirm that maintainability is within the capability of the electrical and mechanical teams. Traditional beginning procedures are more suitable for scenarios where the crew has rudimentary instruction. However, further training is needed if a complex beginning and regulating mechanism are required.

 

Comfort Of Use: its connected interface must contain provisions for easy control and feedback, such as clear representations, operator panels, and indications. Diagnostic and repair manuals are also required.

 

Restriction Of Facility Space: The actual floor space offered is important to address, particularly when retrofitting new equipment into an existing location. Extensions could be required, increasing the overall cost of purchasing the equipment. Additional control mechanisms are required when working with current beginning procedures to maintain an appropriate working environment. Heat dissipation allotment for different components like transformers, transistors, and power supply is included.

 

Various Top Brands to Purchase Control Motor Starters

 

Crompton Motor S: Crompton Greaves Consumer Electricals Ltd (commonly known as Crompton) is a Mumbai-based Indian electronic equipment firm. The firm makes available LED lights, fans, motors, and home appliances such as water heaters, air conditioners, and kitchen appliances.


 

L&T: Larsen & Toubro Limited, or L&T, is a Mumbai-based Indian multinational corporation interested in building, engineering, manufacturing, information technology, technology, and financial services. The corporation is ranked among the top 5 construction firms in the globe.


 

KSB: Its extensive range includes a solution for any fluid handling difficulty. KSB is the knowledgeable partner you may depend on for every application, from industrial motors and valves to automation systems for pumps & pump equipment and energy conservation and repair services. You may discover full specs, statistics, and literature about all products in KSB.


 

Siemens: Siemens has already developing and producing world-class control devices for over 125 years. Siemens provides a diverse selection of starters to meet the needs of various industries. These items give a smart, simple, dependable motor starting option. They use tried-and-true Siemens contactors & relays to provide the proper start for motors that require direct online beginning or star Delta beginning.

 

Havells: Havells are well known for their high-quality products. Their dual-coated copper winding wires give high efficiency to the motors. Winding wires can withstand high temperatures, and this protects them from burning. Unlike most of the pumps available in the market have ordinary enameled copper wire or wire windings, which makes them inefficient.

 

Purchase Best Quality Control Motor Starters from Moglix

 

Manual motors are employed to manually turn on and off motors and provide fuse-free safety against overload, short circuits, and phase faults. Moglix's control motor starting category includes a broad range of manual engine starters, underwater pumps, and automatic motor starters to meet the demands of customers. The manual engine starters in this category have an encased and hermetically protected coil that is waterproof & shockproof. Single phase, phasing imbalance, and phasing reversal are all protected by our automated motor starters.

 

Popular Links -
 

Water Pumps | Motors | Control Motor Starters | Pump Accessories | Centrifugal Pumps | Submersible Pumps | Sewage Pumps | Booster Pumps | Shallow Well Pumps | Gear Pumps | Washer Pumps | General Purpose Motors | Submersible Pump Starters | Automatic Motor Starters | Manual Motor Starters | Spring Mounts | Gardening & Landscaping | Electricals | Wires & Cables | Switches & Sockets | Power Generation & Transformers | Micro Drives | Distribution Boards | Relays & Contactors | Electrical Spares & Accessories | Wire & Cable Accessories | HVAC Control Products & Sensors | Switches | Extension Boards | Boxes | Plugs & Sockets | Electrical Sockets | Switch & Socket Combinations | Lamp Holder | Flexicords | Door Bell | Indicator Switch | Motor Starter Switches | Ceiling Rose | Cord Switches | Volume Controller | Telephone Jack | Computer Jacks | Receptors | Plates with Base Frame | Base Frame | Cover Plates | DLP Trunking | Plug & Connectors | Receptacles

Frequently Asked Questions about Control Motor Starters

When Standard starters are sufficient for motor control?

In order to prevent damage from being done to DC motors during startup due to extremely high current and torque, starters are utilised. They achieve this by connecting the motor's armature winding in series with external resistance, which limits the current to a manageable amount.

Why motor starting current is high?

Because the motor's slip is equal to unity at start, the rotor's reactance is large. As the slip decreases, the value of Rr/s rises. The induction motor draws a significant amount of inductive current when it is started because the rotor reactance is greater than the rotor resistance.